You are here: Distributor Pompa Air»Direct Coupled Volute Pump

Direct Coupled Volute Pump

KSB Mega CPK-Horizontal radially split volute casing pump

Design

KSB Mega CPK
Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Also available as variant with “wet” shaft. ATEX-compliant version available.

KSB-Mega CPK

▪ Volute casing pump

▪ Horizontal installation

▪ Back pull-out design

▪ Single-stage

▪ Meets the technical requirements to ISO 5199

▪ Dimensions and ratings to ISO 2858 complemented by pumps of nominal diameters DN 25, DN 200 and above

 

Pump casing

▪ Single or double volute, depending on the pump size
▪ Radially split volute casing
▪ Volute casing with integrally cast pump feet
▪ Replaceable casing wear rings (as required)
Impeller type
▪ Closed radial impeller with multiply curved vanes
Shaft seal
▪ Gland packing
▪ Commercial single and double mechanical seals
▪ Commercial cartridge seals
▪ Shaft fitted with a replaceable shaft protecting sleeve in the shaft seal area
Alternative:
▪ Version without shaft protecting sleeve with “wet shaft” (in Europe and
Northern Asia only)
Bearings
Bearings:
▪ Medium-duty
– Radial bearing: cylindrical roller bearing
– Fixed bearing: paired angular contact ball bearings / double-row angular
contact ball bearing
▪ Economy
– Floating bearing assembly: deep groove ball bearings
Lubrication:
▪ Oil lubrication
▪ Grease lubrication

Applications

Handling of aggressive liquids in the chemical and petrochemical
industries as well as in refinery

Overview of technical data

KSB-Mega CPK Configuration
Type of impeller Closed / Radial
Type of installation Long- coupled
Maximum drive rating 90 kW
Impeller material (EN standard) 1. 4593 / 1.4517 / A995GRCD4MC;GP240GH+N/ A216GRWCB;JL1040/ A48CL35
Type of bearing Ball bearings
Drive frequency 50 Hz / 60 Hz
Maximum speed of rotation 4 1/min
Maximum flow rate 1. 160 m³/h
Maximum discharge-side pressure 25 bar
Casing material (EN standard) DUPLEX STAINLESS STEEL 1. 4593/;GREY CAST IRON JL1040 / A48CL3;STAINLESS STEEL 1.4408 / A743;STEEL GP240GH+N/ A216 GR WCB
No. of impeller entries Single entry
Integrated control system Yes
Minimum flow rate 2 m³/h
Suction characteristics Non- priming
Drive voltage Low voltage
Pull-out design Yes
Pump set location Dry installed
Heatable Yes
Max. permissible fluid temperature 400 °C
Main applications Industry and process engineering; Oil / Gas
Type of casing Volute casing
Type of connection Flange
Type of lubrication Grease / Product lubrication
Type of drive Electric motor
Installation position Horizontal
Level indication Grease lubrication
Shaft material (EN standard) ALLOY STEEL 1. 7709+QT+SR;DUPLEX STAINLESS STEEL 1.4462;STEEL C45+N
Type of coupling Direct
Shaft seal type Gland packing; Mechanical seal
Maximum head 162, 00 m
Maximum rated pressure (discharge) PN25
Minimum head 2, 00 m
Nozzle position End suction
Casing partition Radially split

 

EBARA                    GRUNDFOS                     KSB             

KSB - Etanorm GPV / CPV Single-stage volute casing pump,for vertical installation in closed tanks under atmospheric pressure

Design

KSB – Etanorm GPV / CPV
Single-stage volute casing pump, ratings to EN 733, for vertical installation in closed tanks under atmospheric pressure. Up to an immersion depth of 2000 mm.

 

Applications

Handling of neutral degreasing and phosphatizing solutions, wash water with degreasing agents, dipping paints, etc.

 

 KSB-Etanorm GPV-W-CPV-W-modularSectional drawing

1 Motor housing 2, 3 Rolling element bearings
4 Motor stool 5 Cover plate
6 Shaft 7 Overflow opening
8 Intermediate pipe 9 Shaft passage
10 Casing cover 11 Impeller
12 Suction nozzle 13 Discharge nozzle
14 Riser 15 Volute casing
16 Clearance gap

 

 

 

 

 

 

 

 

 

 

 

To transport the pump/pump set suspend it from the lifting tackle as shown below.

KSB-Etanorm GPV-W-CPV-W.dia

 

 

 

Fig. 1: Transporting the pump set without/with cover plate up to motor size 160

 

KSB-Etanorm GPV-W-CPV-W-hor

 

Fig. 2: Transporting the pump set without/with cover plate up to motor size 160 for
larger installation depths

 

Overview of technical data

Type of bearing Rolling element bearings
Casing partition Radially split
Drive frequency 50 Hz / 60 Hz
Type of drive Electric motor
Drive voltage Low voltage
No. of impeller entries Single entry
Maximum submergence 535 mm
Impeller material (EN standard) 1. 4408;JL 1040
Type of coupling Direct
Type of lubrication Grease lubrication
Max. permissible fluid temperature 70 °C
Nozzle position Variable
Maximum rated pressure (discharge) PN 10; PN 16
Pump set location Wet well
Shaft material (EN standard) 1. 4462;C45+N
Standard EN 733
Suction characteristics Non- priming
Top plate Yes
Type of casing Volute casing
Type of impeller Radial; Closed
Type of connection Flange
Casing material (EN standard) 1. 4408;JL 1040
eClass assignment 36410101; 03641000;36410100
Maximum head 100, 00 m
Minimum head 1, 50 m
Installation position Vertical
Shaft seal type Shaft seal ring
Main applications Industry and process engineering; Waste water / sewage
Casing material Cast iron; Stainless steel
Maximum discharge-side pressure 10 bar
Maximum drive rating 90 kW
Type of installation Stationary
Maximum flow rate 750 m³/h
Minimum flow rate 3 m³/h
Maximum speed of rotation 3. 500 1/min

 

 

EBARA            GRUNDFOS             KSB            WILO           TSURUMI

Wilo - Series NFCH For pumping mineral or synthetic

 

Design

Wilo – Series NFCH

Single-stage low-pressure centrifugal
pump mounted on a baseplate

Wilo NFCH-Dia

Application

For pumping mineral or synthetic
heat carrying fluids up to 350 °C, e.g.:
in industrial processes or for power
generation

Q max.

1,000 m³/h
H max.
90 m

 

Technical data

• Permissible temperature range up to
Wilo NFCH-diag+350 °C, dependent on max. operating
pressure:
0 °C … 120 °C (16 bar)
120 °C … 300 °C (13 bar)
300 °C … 350 °C (16 bar)
• Nominal diameter on pressure side
DN 32 to DN 125
• Max. operating pressure PN 16

 

 

 

Equipment/function

• Single-stage, horizontal centrifugal
pump with axial suction connection and
radial pressure upwards-facing pressure
connection
• Dimensions and hydraulic output as
per EN 733
• Self-cooling design with double
temperature barrier allows the use of an
uncooled shaft seal, reducing heat loss.
• Standard mechanical seal corresponding
to heat carrier medium
• Version with or without spacer coupling
• 2 or 4-pole IEC standard motor 50 Hz
• Delivered as complete unit (pump,
coupling, coupling protection, motor
and baseplate) or without motor or only
pump with free shaft end

 

Special features

Impeller diameter is adjusted to the
dutypoint as appropriate
• 60 Hz or ATEX version on request

 

EBARA            GRUNDFOS             KSB            WILO           TSURUMI

KSB-Etaseco Seal-less volute casing pump in back pull-out design with fully

 

 

Design

KSB-Etaseco Horizontal / vertical, seal-less volute casing pump in back pull-out design with fully enclosed canned motor

KSB-etaseco-mudular copyLow noise emission, with radial impeller, singlestage, single-entry, pump casing connecting dimensions to EN 733.

 

 

 

 
Applications

Handling of aggressive, flammable, toxic, volatile, or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.

 

Drive

KSB-Etaseco-CurvesThree-phase, asynchronous canned motor, enclosure IP 55,
without explosionproof status. Thermal motor protection by
means of PTC thermistors. The motor design is in accordance
with IEC 60 034 (DIN VDE 0530).

 

 

 

 

 

Overview of technical data

Type of bearing Plain bearings
Casing partition Radially split
Drive IEC standardized motor
Drive frequency 50 Hz / 60 Hz
Type of drive Electric motor
Drive voltage Low voltage
Connection to power supply 220/ 400/690 V, 3~
No. of impeller entries Single entry
Impeller material (EN standard) JL1040; JS1025
Type of installation Close- coupled
Type of coupling Direct
Type of lubrication Oil / Product lubrication
Max. permissible fluid temperature 140 °C
Nozzle position End suction
Maximum rated pressure (discharge) PN 16
Pull-out design Yes
Pump set location Dry installed
Shaft material (EN standard) 1. 4021
Suction characteristics Non- priming
Type of casing Volute casing
Type of impeller Multi- vane impeller;Closed;Closed / Radial;Radial
Type of connection Flange
Casing material (EN standard) JS1025; JL1040
eClass assignment 36410100; 36410101;36410000
Maximum head 100, 00 m
Minimum head 9, 00 m
Installation position Horizontal or vertical
Shaft seal type Canned motor pump
Main applications Industry and process engineering
Casing material Cast iron; Nodular cast iron
Maximum discharge-side pressure 16 bar
Maximum drive rating 18 kW
Type of installation Stationary
Maximum flow rate 250 m³/h
Minimum flow rate 3 m³/h
Maximum speed of rotation 3. 500 1/min

 

EBARA            GRUNDFOS             KSB            WILO           TSURUMI

EBARA-UD-Pressure Booster Unit

 

APPLICATION

1. Domestic : High-rise buildings, Condominiums, Apartments etc.
2. Commercial : Office buildings, Hotel, Shopping centres etc.
3. Industrial : High-rise factory, Manufacturing & processing industries applications etc.
4. Social service : School, Hospitals etc.

 

FEATURES

1. All components are integrated on a rugged steel base. It is ready for use by only connecting with
supply piping and to the power source.
2. Layout is very compact and much lighter than conventional units. It occupies lesser space and requires
easier installation than conventional units.
3. The flow control system which prevent frequent start and stop of pumps, requires small hydropneumatic
pressure tank and ensures constant fresh water supply
4. Pumps are in parallel operation for high demand and alternating in low demand, suitable for energy
saving

Booster Ebara FSA

CONTROL SYSTEM

Step 1) both pumps are stopped when water tank is fully charged. In
this condition water is supplied from the pressure tank and
water pressure in tank gradually decreases.
Step 2) No. 1 pump start at pressure P1 (point 1) and water supplied
from pump and pressure tank.
Step 3) When more water is required and water pressure decreases to
P2 (point 2), no. 2 pump also starts, operation point shifts to
point 3 and system shifts to parallel operation.
Step 4) When water consumption decreases, water pressure in tank
increase and when pressure reaches P3 (point 4) no. 2 pump
is stopped and operation point shifts to point 5.
Step 5) when water consumption further decreases, water pressure in
tank increases and pressure switch is turned off and the flow
switch used to detect small flow is turned off. When both
pressure and flow switch are off, no. 1 pump stops (point 6).
Flow switch setting point is at small capacity point; therefore
pump continuous operation range is much wider. Accordingly
pump start frequency is greatly decreased

 

GENERAL SPECIFICATION

Ebara-UDP-FSA Bosster UnitDescription Standard Optional


Liquid handled property Fresh water, 0 – 40 0C
Installation Indoor Outdoor
Operation system
Pump speed Constant
Control Control with pressure switch & flow switch
Mode Parallel or alternate running
Power source AC, 3 phase, 50Hz, 380V AC,1 phase, 50Hz, 220V
(refer to model)
Max. working pressure 6 – 10 kg/cm2
Allowable suction head Min.: -0.3 kg/cm2, Max.: Refer to model
Pump model CDX, 2CDX, 3S and FSA
Control panel
Starting method DOL (Up to 5.5 kW) or Star-Delta (5.5 to 15 kW)
Construction Dust proof type
Operation key Touch panel key type
Pressure tank
Construction Air pre-charged diaphragm type
Capacity 18 to 60 litre

 

 

EBARA              GRUNDFOS              KSB             WILO           TSURUMI

KSB-CPKN-SX Sprinkler systems to VdS and fire protection Pump

 

 

 

Design

KSB-CKPN-MODULARHorizontal, long-coupled, single-stage volute casing pump in back pull-out design. Replaceable shaft protecting sleeves and casing wear rings.

Applications

Sprinkler systems to VdS and fire protection.

 

 

 

 

 

 

Overview of technical data

Type of bearing Ball bearings
Casing partition Radially split
Drive frequency 50 Hz / 60 Hz
Type of drive Electric motor, turbine, I.C. engine
Drive voltage Low voltage
No. of impeller entries Single entry
Impeller material (EN standard) 1, 4408
Type of installation Long- coupled
Type of coupling Direct
Type of lubrication Oil lubrication
Max. permissible fluid temperature 20
Nozzle position End suction
Maximum rated pressure (discharge) 25 BAR
Pull-out design Yes
Pump set location Dry installed
Shaft material (EN standard) 1. 4057;1.4462
Suction characteristics Non- priming
Suitable for drinking water Yes
Type of impeller Radial; Closed;Multi-vane impeller
Type of connection Flange
Casing material (EN standard) JS1025
eClass assignment 36410101; 36410000;36410100
Maximum head 163, 00
Minimum head 84, 00 m
Shaft seal type Mechanical seal; Gland packing
Main applications Industry and process engineering; Building services;Water
Casing material Cast iron
Maximum discharge-side pressure 25 bar
Maximum drive rating 250 kW
Type of installation Stationary
Maximum flow rate 468 m³/h
Minimum flow rate 82 m³/h
Maximum speed of rotation 3 1/min

Fire protection is a question of experience

Application-cpkn-sx_KSB
KSB leads the European sprinkler pump market – with good reason. Our experience in fire protection stretches back more than
40 years. And KSB makes its products on every continent. That
international presence is a major advantage in fire protection –
we know our way through all the standards, certifications and
regulations and are represented by fire protection experts in over
100 countries. We have the right pumps and components to
match central Europe’s VdS standard, the UK’s LPC BS 5306-2,
Spain and Portugal’s CEPREVEN, European standard EN 12845,
NFPA20/FM/UL in the USA, and a host of other national standards.
For us, quality includes delivering ideal technology. But that is
just part of our first-class service. More than 1,600 KSB specialists
in over 100 service centres provide skilled help, fast. Whether
your building is just being planned or older than all its occupants,
KSB stops fires before they really get started. Water relief!

 

EBARA            GRUNDFOS           KSB          WILO        TSURUMI

KSB-MHD Slurry Pumps

 

Design

KSB-MHD-ModularDesigned to provide high flow/medium head with high efficiency for high
volume transportation in long pipelines.

Horizontal end suction construction. Single wall pump shell
with replaceable suction side liner; four vane impeller or
three vane option for larger size solids.

 

Applications

Mineral processing (oil sands, copper, gold, iron ore, nickel, phosphate, coal)

• Power Generation
• Aggregate (sand & gravel)
• Ash Handling
• Flue Gas Desulfurization
• Thickener & Tailings
• Mine Dewatering
• Industrial Slurries
• Dredge

 

Wear Parts

1. Impeller is designed for wear-resistant operation in
highly abrasive slurries using GIW’s flow simulation
computer program.
2. Two aramid gaskets aid in the removal of the impeller.
3. Replaceable suction liner facilitates pump internal
inspection and minimizes wear part usage and cost.
Liner can be rotated at intervals to increase wear life.
4. Pump shell is computer designed to optimize wear
and efficiency.

 

Shaft Seal

KSB-MHD-LSA-Shaftseal5. Replaceable wear plate maximizes stuffing box life.
Reduced water consumption options available.
6. Shaft sleeve with fused carbide wear resistant coating
to maximize packing life

 

Mechanical End

KSB MHD-Curves7. Robust stiffened shaft to improve the wear life
of the mechanical end and stuffing box.
8. Impeller release ring for safe and easy impeller
removal. Feature is standard on larger pump sizes.
9. Spring retainer ring locates the thrust bearing
preload springs for correct axial thrust load.
10. Radial bearings are a heavy duty, self-aligning,
double-row, spherical roller-type design.
11. Split-cartridge bearing assembly offers ease of
inspection and maintenance.
12.Accurate impeller clearance adjustments are easily
made with the adjusting screw.
13. Labyrinth seals protect bearings.

 

Quick Alignment

14. Rabbet fits machined in the pedestal support the
shell and provide component alignment.

 

EBARA            GRUNDFOS           KSB          WILO        TSURUMI

Ebara-GP-Gear pumps

 

 

Ebara-Gear Pumps

Features :

  • Ebara-Gear PumpCompact style and light weight
  • Large capacity with small power input
  • Long life and highly reliability
  • Quick delivery and low price
  • Adjustable    relief valve

 

 

 

 

 

Applications :

  • Supplying oil for machinery
  • Fuel transfer
  • Low pressure transmission
  • Oil burner injection

Detail Ebara Gear pump

 

EBARA            GRUNDFOS           KSB          WILO        TSURUMI

KSB-Mega

 

KSB-MEGA Horizontal, end suction, modified volute casing

KSB-MEGA_1Application

The GIW Mega Slurry is a high-performance, lowmaintenance slurry pump recommended for coarse
or fine particles from solids laden waste water to
aggressive slurries of an abrasive and/or corrosive
nature.Consult factory for corrosive applications.

Design

Horizontal, end suction, modified volute casing
pump includes three vane, open design impeller
for large solids passage and good wear
characteristics over a broad operating range. The
single stage, compact arrangement allows easy
maintenance of wet end components. The back
pull-out design permits removal of the mechanical
end without disturbing the wet end or piping.

KSB_mega Casing

The pump casing is horizontal volute casing, one piece casting with integral mounting foot.

 Shaft

The shaft is dry design, protected by an easily renewable shaft sleeve in the gland sealing area. The impeller threads on the
pump end of the shaft and a keyway is provided on the drive end to attach the coupling or pulley.

 Shaft Sealing

The entry of the shaft into the pump is sealed by standard gland packing or by an optional mechanical seal.

 

 

EBARA            GRUNDFOS           KSB          WILO        TSURUMI

KSB - Etanorm

 

 

 

 

Etanorm modularDesign
The KSB Etanorm is Horizontal, long-coupled, single-stage volute casing pump with ratings and main dimensions to EN 733 in back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings. Design to ATEX.
Applications
Spray irrigation, irrigation, drainage, district heating, water supply systems, heating and air-conditioning systems, condensate transport, swimming pools, fire-fighting systems, handling of hot water, cooling water, fire-fighting water, oil, brine, drinking water, brackish water, service water, etc.

 

Overview of technical data
Type of bearing Ball bearings
Casing partition Radially split
Drive frequency 50 Hz / 60 Hz
Type of drive Electric motor
Drive voltage Low voltage
Explosion protection IP 55
No. of impeller entries Single entry
Impeller material (EN standard) 1. 4408 / A743 GR CF8 M;CC480K-GS / B30 C90700;JL1040 / A 48 CL 35B;LTB2
Type of installation Long- coupled
Type of coupling Direct
Type of lubrication Grease / Oil lubrication
Max. permissible fluid temperature 140 °C
Nozzle position End suction
Maximum rated pressure (discharge) 16 BAR
Pull-out design Yes
Pump set location Dry installed
Shaft material (EN standard) C45; 1.4462
Standard EN; EN / ANSI
Suction characteristics Non- priming
Type of casing Volute casing
Type of impeller Radial; Multi-vane impeller;Closed;Closed / Radial
Type of connection Flange
UNSPSC classification 4015150300
Casing material (EN standard) 1. 4408 / A743 GR CF8 M;CC480K-GS / B30 C90700;JL1040 / A 48 CL 35B;JS1030 / A536 GR 60-40-18
eClass assignment 00000000; 36410000;36410101;36410100
Maximum head 160, 00 m
Minimum head 3, 00 m
Installation position Horizontal
Shaft seal type Mechanical seal; Gland packing
Main applications Oil / Gas;Waste water / sewage;Water;Building services;Energy;Industry and process engineering
Casing material Cast iron; Chrome nickel steel;Cast stainless steel;Nodular cast iron;Bronze
Maximum discharge-side pressure 16 bar
Type of installation Stationary
Maximum flow rate 660 m³/h
Minimum flow rate 1, 50 m³/h
Maximum speed of rotation 4. 400 1/min

 

 

EBARA            GRUNDFOS           KSB          WILO        TSURUMI

Pages:12Next »