You are here: SUKMA Tirta Persada - Distributor Pompa Air»Hot water heating systems

Hot water heating systems

EBARA-3-3L SERIES Centrifugal pumps close coupled and standardized

EBARA-3-3L SERIES

Centrifugal pumps close coupled and standardized

Ebara-3-Series

CENTRIFUGAL ELECTRIC PUMPS END SUCTION IN COMPLIANCE WITH EN 733
(FORMER DIN 24255)
End suction centrifugal pumps built in stainless steel AISI 304
(3 Series) and AISI 316L (3L Series)


APPLICATIONS

• Water supply to civil, agricultural and industrial plants
• Pressure boosting
• Fire-fighting, heating systems and air-conditioning
• Moving industrial liquids
• Irrigation
• Refrigeration towers
• Swimming pools
• Emptying
• Washing plants


TECHNICAL DETAILS

Ebara-3-Series-contruction• Can also work in vertical position
• Highly resistant contruction
• Hydroforming process EBARA patent

PUMP TECHNICAL DATA

• Maximum working pressure: 10 bar
• Maximum temperature of the liquid:
-10°C ÷ +90°C
-10°C ÷ +110°C (L-H-HS-HW-HSW-E versions)
-10°C ÷ +120°C (ES version)
• MEI >0,4 for SERIES 3(L) 2 poles, MEI >0,1 for SERIES 3(L) 4 poles
For further information please see our Data Book

MOTOR TECHNICAL DATA

• High efficiency IE2 motors starting from 0,75kW
• Self-ventilated 2 and 4 poles asynchronous motor
• Class of insulation F (B for high temperatures)
• IP 55 protection degree
• 230V ±10%, 50Hz single phase voltage,
three phase voltage 220-240/380-415V ± 5% (up to 0,55kW included), 50Hz for 3(L)M4 SERIES,
three phase voltage 230/400V ±10% (from 0,75kW to 4kW included), 50Hz for 3(L)M4 SERIES,
three phase voltage 230/400V ±10% (up to 4kW included), 50Hz for the other models
three phase voltage 400/690V ±10% (from 5,5kW and over), 50Hz
• Protection is user’s responsibility

MATERIALS

Ebara-3-Series-contruction1 copy• Pump casing and seal housing disc:
– AISI 304 per 3 Series 32-125/160/200
40-125/160/200
50-125/160
65-125/160/200
– AISI 316L for 3L Serie 32-125/160/200
40-125/160/200
50-125/160
65-125/160/200
– AISI 316 microcasted for 3L Series 65-250
80-160/200/250
• Impeller in:
– AISI 304 for 3 Series 32-125/160/200
40-125/160/200
50-125/160
– AISI 316L for 3L Series 32-125/160/200
40-125/160/200
50-125/160
– AISI 316 microcasted for 3 SERIES 65-125/160/200
3L SERIES 65-125/160/200
65-250
80-160/200/250
• Standard mechanical seal:
– Carbon/Ceramic/NBR for 3 Series 32-125/160/200
40-125/160/200
50-125/160
65-125/160/200
– SiC/SiC/FPM for 3L Series 32-125/160/200
40-125/160/200
50-125/160
65-125/160/200/250
80-160/200/250
– Special mechanical available on request

EBARA               GRUNDFOS              KSB              WILO          TSURUMI

KSB-Rio C Hot water heating systems and heat recovery systems

 

 

KSB-Rio C Hot water heating systems and heat recovery systems

 

Design

Maintenance-free, glandless wet rotor pump, screw-ended, with three speed levels.

 

KSB-RIO-C-Dim

Applications

Hot water heating systems, heat recovery systems and cooling circuits in air-conditioning systems.

KSB-RIO-C-CURV

 

Overview of technical data

Type of bearing Plain bearings
Drive Electric motor
Drive frequency 50 Hz
Type of drive Electric motor
Drive voltage Low voltage
Connection to power supply 230 V, 1~
Impeller material (EN standard) KUNSTSTOFF
Type of installation In- line
Type of coupling None
Type of lubrication Oil / Product lubrication
Max. permissible fluid temperature 110 °C
Nozzle position In- line
Maximum rated pressure (discharge) PN 10
Pump set location Dry installed
Shaft material (EN standard) EDELSTAHL X40 CR13
Suction characteristics Non- priming
Suitable for drinking water Yes
Type of casing Volute casing
Type of impeller Closed / Radial;Closed
Type of connection Thread
UNSPSC classification 4015150300
Casing material (EN standard) EN- GJL-200
eClass assignment 36410101; 36410100;36410000;36410105
Maximum head 5, 60 m
Minimum head 0, 25 m
Installation position Any
Shaft seal type Seal- less
Main applications Building services; Water
Casing material Cast iron
Maximum discharge-side pressure 10 bar
Maximum drive rating 0. 10 kW
Type of installation Stationary
Maximum flow rate 3, 60 m³/h
Maximum speed of rotation 2. 200 1/min

 

EBARA            GRUNDFOS            KSB            WILO          TSURUMI

KSB-Rio N / Z N Circulator Pumps with Manual Speed Control

 

Design

KSB-Rio N / RIO Z N

Maintenance-free, glandless wet rotor pump, flanged or screw-ended, with three speed levels; in twin pump design (Rio Z) for standby operation with integrated swing check valve or, on option, peak load operation (parallel operation).

KSB-Rio.N-ZN

Applications

Hot water heating systems, heat recovery systems and cooling circuits in air-conditioning systems.

 

Operating modes

▪ Different speed levels

 

Automatic functions

▪ Full motor protection with integrated trip electronics
(from size 25-70 motor protection to be provided by the
operator)

 

 

Overview of technical data
Type of bearing Plain bearings
Drive Electric motor
Drive frequency 50 Hz / 60 Hz
Type of drive Electric motor
Drive voltage Low voltage
Connection to power supply 400 V, 3~; 230 V, 1~
Impeller material (EN standard) POLYPROPYLEN
Type of installation In- line
Type of coupling None
Type of lubrication Oil / Product lubrication
Max. permissible fluid temperature 120 °C
Nozzle position In- line
Maximum rated pressure (discharge) PN 10
Pump set location Dry installed
Shaft material (EN standard) X 46 CR 13
Suction characteristics Non- priming
Type of casing Volute casing
Type of impeller Closed / Radial
Type of connection Screw- ended, flange
UNSPSC classification 4015150300
Casing material (EN standard) EN- GJL-250
eClass assignment 36410105; 36410101;36410100;36410000
Maximum head 4, 00 m
Installation position Horizontal or vertical
Shaft seal type Seal- less
Main applications Building services; Water
Casing material Cast iron
Maximum discharge-side pressure 10 bar
Type of installation Stationary
Maximum flow rate 76 m³/h
Maximum speed of rotation 2. 800 1/min

 

EBARA            GRUNDFOS           KSB          WILO        TSURUMI

Grundfos- UP-UPS Circulator pumps

 

 

Overview

Grundfos-UPS-UPAUPS pumps constitute a complete range of 3-speed circulator pumps, available both in 50 and 60 Hz.

The pumps can be used in both open and closed systems. UPS pumps are of the canned-rotor type, i.e. pump and motor form an integral unit without a shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid.

 

Applications

UPS pumps are designed for circulation of liquids in heating and air-conditioning systems. Pumps with bronze or stainless steel housings are also suitable for use in hot-water service systems. Examples of typical applications are:

  • One- and two-pipe heating systems
  • Main pumps
  • Zone pumps
  • Boiler shunt pumps
  • Pumps for heating surfaces
  • Calorifiers
  • Underfloor heating systems
  • Solar heating systems
  • Heat pump systems
  • Geothermal heating systems
  • Heat recovery systems
  • Two-pipe air-conditioning systems
  • Pumps for refrigeration units.

 

Features and benefits

  • UP-UPS-CurveMaintenance-free
  • Low noise
  • Low energy
  • Complete range
  • Available with corrosion-resistant stainless steel or bronze pump housing
  • Wide range of accessories.

 

 

 

 

 

 

 

 

 

EBARA            GRUNDFOS           KSB          WILO        TSURUMI

Wilo-CronoBloc-BL-Glanded pump

 

 

Wilo-CronoBloc-BLDesign

Glanded pump in block design with flange connection

Application

For pumping cold and hot water (in accordance with VDI 2035) without abrasive substances in heating, cold water and cooling water systems

 

Special features / product benefits

  • High-efficiency motors as standard; from 0.75 kW nominal motor power: motors with IE2 technology
  • Reduced life cycle costs due to optimised efficiency
  • High corrosion protection due to cataphoretic coating of the cast iron components
  • Standard condensate drainage holes in the motor housings
  • Application benefits in air-conditioning and cooling systems due to direct condensate drainage by means of optimised lantern design
  • Bidirectional mechanical seal with forced flushing
  • High worldwide obtainability of standard motors (according to Wilo specifications) and mechanical seals
  • Meets user requirements due to performance and main dimensions in accordance with EN 733 (DIN for norm pumps)

Technical data

  • Wilo_Crono-Bloc_BL-DMPermissible temperature range ‐20°C to +140°C
  • Mains connection 3~400 V, 50 Hz
  • Protection class IP 55
  • Nominal diameter DN 32 to DN 125
  • Max. operating pressure 16 bar (optionally 25 bar on request)

 

 

Description/design

Single-stage low-pressure centrifugal pump in block design, with axial suction port and radially arranged pressure port with

  • Mechanical seal
  • Flange connection with pressure measuring connection R 1/8
  • Lantern
  • Coupling
  • IEC standard motor

 

EBARA            GRUNDFOS           KSB          WILO        TSURUMI

KSB-HPK

 

KSB-hpk-modular-1Design

KSB-HPK Series

Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. TÜV certification to TRD on option. Design to ATEX.

 

Applications

KSB-hpk-app

 

KSB-HPK Series

Handling of hot water and thermal oil in piping or tank systems, particularly in medium-sized and large hot water heating systems, forced circulation boilers, district heating systems, etc.

Overview of technical data

Type of bearing Rolling element bearings
Casing partition Radially split
Drive frequency 50 Hz / 60 Hz
Type of drive Electric motor
Drive voltage Low voltage
No. of impeller entries Single entry
Impeller material (EN standard) JS 1030; JL 1040;1.4408
Type of installation Long- coupled
Type of coupling Direct
Type of lubrication Oil lubrication
Max. permissible fluid temperature 240 °C
Nozzle position End suction
Maximum rated pressure (discharge) PN 40
Pull-out design Yes
Pump set location Dry installed
Shaft material (EN standard) C45+ N
Suction characteristics Non- priming
Type of casing Volute casing
Type of impeller Radial; Closed
Type of connection Flange
Casing material (EN standard) JS 1025; 1.7706;GP240GH+N
eClass assignment 36410000; 36410100;36410101
Maximum head 275, 00 m
Minimum head 2, 00 m
Installation position Horizontal
Shaft seal type Mechanical seal; Gland packing
Main applications Industry and process engineering; Energy;Building services
Casing material Cast steel; Nodular cast iron
Maximum discharge-side pressure 40 bar
Maximum drive rating 3. 200 kW
Type of installation Stationary
Maximum flow rate 4. 800 m³/h
Minimum flow rate 1 m³/h
Maximum speed of rotation 3. 500 1/min

 

EBARA            GRUNDFOS           KSB          WILO        TSURUMI

Ksb-Etaline-R

 

 

 

 

KSB-Etaline-RKsb-Etaline-R

Design
Vertical close-coupled, in-line circulator pump with volute casing and standardized motor.
Applications 
Hot water heating systems, cooling circuits, air-conditioning, water and service water supply systems, industrial recirculation systems.

 

 

Overview of technical data
Type of bearing Ball bearings
Casing partition Radially split
Drive IEC standardized motor, electric motor
Drive frequency 50 Hz / 60 Hz
Type of drive Electric motor
Drive voltage Low voltage
Connection to power supply 400 V, 3~
Impeller material (EN standard) 1. 4408;CC480K-GS;JL1040
Type of installation Close- coupled
Type of coupling Direct
Type of lubrication Oil lubrication
Max. permissible fluid temperature 140 °C
Nozzle position In- line
Maximum rated pressure (discharge) PN25
Pull-out design Yes
Pump set location Dry installed
Shaft material (EN standard) 1. 4057;C45
Suction characteristics Non- priming
Type of casing Volute casing
Type of impeller Closed / Radial
Type of connection Flange
Casing material (EN standard) JL1040; JS 1025
eClass assignment 36410000; 36410100;36410101;36410105
Maximum head 97, 00 m
Installation position Horizontal or vertical
Shaft seal type 00
Main applications Industry and process engineering; Water;Building services
Casing material Carbon steel
Type of installation Stationary
Maximum flow rate 1. 900 m³/h
Minimum flow rate 60 m³/h
Maximum speed of rotation 1. 750 1/min

 

 
EBARA               GRUNDFOS              KSB              WILO          TSURUMI

Wilo-CronoNorm-NL Centrifugal pump with axial suction point

wilo_nl_modularDesign:
Wilo-CronoNorm-NL single-stage low-pressure centrifugal pump with axial suction point, according to EN 733 and ISO 5199, mounted on a baseplate

Application:

Pumping clean or slightly contaminated water (max. 20 ppm) without solid matter for circulation, transfer and pressure boosting purposes
Pumping heating water in accordance with VDI 2035, water/glycol mixtures, cooling/cold water and industrial water.
Applications in municipal water supply, irrigation, building services, general industry, power stations, etc.

Special features/product advantages

Burgmann mechanical seal with conical sealing chamber
Brand shaft protection
SPM connections for vibration and temperature sensors
Shaft deflection according to DIN ISO 5199
Permanently lubricated, generously dimensioned ball bearings (2Z version)

Materials

Pump housing
Grey cast iron spiral with anti-rotation ribs.
With axially aligned suction piece and radial pressure ports and cast assembly feet.
Dimensions and hydraulics are in accordance with DIN EN 733
Flange PN 16 in accordance with DIN 2533 (DN 200 ‐ PN 10/DIN 2532)
Standard mechanical shaft seal AQ1EGG for water up to 140°C
Stuffing box for water up to 110°C

Description/design ;

Wilo-chart_nl2Single-stage low-pressure centrifugal pump as baseplate pump with axial suction piece with flanged bearing bracket and axis mounting for flexibly coupled drives.
Spacer coupling (sleeve coupling) available as an option; they make it possible to leave the motor in position when removing the rotor unit
Shaft deflection meets the requirements of ISO 5199

Qmax:  3000.0 m3/h
Hmax:  140.0 m

 

 

EBARA               GRUNDFOS              KSB              WILO