Pompa Submersible Franklin CS Series 5″

Description

Features (Pompa Submersible Franklin CS Series 5″)

  • Easy installation: the single phase version have internal capacitor and thermic motor-protection thus is not necessary to connect the pump to a control panel
  • Compact close-coupled design, robust and rust resistant
  • Double mechanical seal separated by an oil* chamber for maximum motor protection (*In compliance with FDA – Food, Drug Administration – and the annex to G.U. no. 104 of 20/04/73 for oils in contact with food stuffs)
  • Plug-in type power cable and level control (floater) for easy replacement
  • Over size motor shaft
  • Stainless steel water proof capsule to protect the motor
  • Motor cooling is guaranteed by the pumped liquid

Specifications

  • Flow:
  • up to 7.5 m³/h at 50 Hz
  • up to 9 m³/h at 60 Hz
  • Head:
  • up to 88 m at 50 Hz
  • up to 80.5 m at 60 Hz
  • Discharge outlet 1¼” Rp or NPT
  • Maximum immersion depth: 20 m
  • Maximum allowable amount of sand: 50 gr/m³
  • Maximum solids size: up to 2 mm
  • Liquid temperature range: from -5 °C to 40 °C
  • Continuous operation either in vertical or horizontal position
  • 20 m of power cable type H07RN F is supplied with the standard version

3 CS – Hydraulic Performances at 50 Hz

Model No.
stages
RATED
POWER
Q = DELIVERY
l/min 0 25.0 33.3 42 50.0 58.3 67 75.0
m³/h 0 1.5 2 2.5 3 3.5 4 4.5
US GMP 0 6.6 8.8 11.0 13.2 15 17.6 19.8
[kW] [HP] H = TOTAL HEAD METERS COLUMN OF WATER [m]
3 CS 3 0.55 0.75 34 30.5 28.5 26.5 23.5 21 17.5 14
4 0.55 0.75 45 40 37.5 34.5 31 27 23 18
5 0.75 1 56 49 46 42 38 33 27.5 21.5
6 0.75 1 66.5 58 54 49.5 44.5 38.5 32 25
7 0.9 1.2 77.5 68 63.5 58 52 45 37.5 29.5
8 1.1 1.5 88 77 71.5 65 58 50.5 42 32.5

5 CS – Hydraulic Performances at 50 Hz

Model No.
stages
RATED
POWER
Q = DELIVERY
l/min 0 42 50.0 58.3 67 75.0 83.3 92 100.0 116.7 125
m³/h 0 2.5 3 3.5 4 4.5 5 5.5 6 7 7.5
US GMP 0 11.0 13.2 15 17.6 19.8 22.0 24.2 26 30.8 33
[kW] [HP] H = TOTAL HEAD METERS COLUMN OF WATER [m]
5 CS 3 0.55 0.75 34.5 31 30 29 28 26.5 25 23.5 22 17.5 15
4 0.75 1 45.5 40.5 39 38 36.5 35 33 30.5 28 22 19.5
5 0.9 1.2 57 50.5 49 47.5 45.5 43.5 41 38 35 27.5 23
6 1.1 1.5 68 59.5 58 55.5 53 50.5 47.5 44 40.5 31.5 26

3 CS – Hydraulic Performances at 60 Hz

Model No.
stages
RATED
POWER
Q = DELIVERY
l/min 0 33.3 42 50.0 58.3 67 75.0 83.3 92
m³/h 0 2 2.5 3 3.5 4 4.5 5 5.5
US GMP 0 8.8 11.0 13.2 15 17.6 19.8 22.0 24.2
[kW] [HP] H = TOTAL HEAD METERS COLUMN OF WATER [m]
3 CS 3 0.75 1 49 43 40.5 37.5 34.5 31 27.5 23 19
4 0.9 1.2 65 55.5 52.5 49 44.5 40 35 29.5 24
5 1.1 1.5 80.5 69 65 60 55 49 43 36.5 29

5 CS – Hydraulic Performances at 60 Hz

Model No.
stages
RATED
POWER
Q = DELIVERY
l/min 0 50.0 58.3 67 75.0 83.3 92 100.0 116.7 133.3 150
m³/h 0 3 3.5 4 4.5 5 5.5 6 7 8 9
US GMP 0 13.2 15 17.6 19.8 22.0 24.2 26 30.8 35.2 39.6
[kW] [HP] H = TOTAL HEAD METERS COLUMN OF WATER [m]
5 CS 2 0.75 1 33.5 30 29.5 28.5 28 27 26 25 22 19 15
3 0.9 1.2 50 44 43 42 40.5 39 37.5 36 31.5 27 21
4 1.1 1.5 65.5 58 56.5 55 53 51 49 46.5 41 34 26

Catalogs