Design
Non-self-priming multistage pump
Application
- Water supply and pressure boosting
- Commerce and industry
- Washing and spraying systems
- Rainwater utilisation
- Cooling and cold water circuits
Special features / product benefits
- IE2-IEC three-phase AC motor (≥ 0.75 kW)
- Impellers and stage chambers made of 1.4301 stainless steel (AISI 304)
- Pump housing made of EN-GJL-250 cast iron, cataphoretic coated
- All relevant components are KTW, WRAS, ACS certified
- Single-phase AC and three-phase AC versions
Technical data
Mains connection 1~230 V (±10 %), 50 Hz or optionally 220 V (±10 %), 60 Hz
- Mains connection 3~230 V (±10 %), 50 Hz (Δ) or optionally 220 V (±10 %), (Δ), 400 V / 50 Hz (Y) or optionally 460 V (±10 %), 60 Hz (Y)
- Fluid temperature ‐15 to +90 °C
- Max. operating pressure 10 bar
- Max. inlet pressure 6 bar
- Protection class IP 54
- Nominal diameters of pipe connections on pressure side Rp 1 or Rp 1 ¼, depending on type
- Nominal diameters of pipe connections on suction side Rp 1, Rp 1 ¼ or Rp 1 ½, depending on type