Jl. Pahlawan No.45 Kav.2 Rempoa Ciputat Timur Tangerang Selatan

info@distributorpompaair.com

Design

KSB – Etanorm GPV / CPV
Single-stage volute casing pump, ratings to EN 733, for vertical installation in closed tanks under atmospheric pressure. Up to an immersion depth of 2000 mm.

 

Applications

Handling of neutral degreasing and phosphatizing solutions, wash water with degreasing agents, dipping paints, etc.

 

 KSB-Etanorm GPV-W-CPV-W-modularSectional drawing

1 Motor housing 2, 3 Rolling element bearings
4 Motor stool 5 Cover plate
6 Shaft 7 Overflow opening
8 Intermediate pipe 9 Shaft passage
10 Casing cover 11 Impeller
12 Suction nozzle 13 Discharge nozzle
14 Riser 15 Volute casing
16 Clearance gap

 

 

 

 

 

 

 

 

 

 

 

To transport the pump/pump set suspend it from the lifting tackle as shown below.

KSB-Etanorm GPV-W-CPV-W.dia

 

 

 

Fig. 1: Transporting the pump set without/with cover plate up to motor size 160

 

KSB-Etanorm GPV-W-CPV-W-hor

 

Fig. 2: Transporting the pump set without/with cover plate up to motor size 160 for
larger installation depths

 

Overview of technical data

Type of bearingRolling element bearings
Casing partitionRadially split
Drive frequency50 Hz / 60 Hz
Type of driveElectric motor
Drive voltageLow voltage
No. of impeller entriesSingle entry
Maximum submergence535 mm
Impeller material (EN standard)1. 4408;JL 1040
Type of couplingDirect
Type of lubricationGrease lubrication
Max. permissible fluid temperature70 °C
Nozzle positionVariable
Maximum rated pressure (discharge)PN 10; PN 16
Pump set locationWet well
Shaft material (EN standard)1. 4462;C45+N
StandardEN 733
Suction characteristicsNon- priming
Top plateYes
Type of casingVolute casing
Type of impellerRadial; Closed
Type of connectionFlange
Casing material (EN standard)1. 4408;JL 1040
eClass assignment36410101; 03641000;36410100
Maximum head100, 00 m
Minimum head1, 50 m
Installation positionVertical
Shaft seal typeShaft seal ring
Main applicationsIndustry and process engineering; Waste water / sewage
Casing materialCast iron; Stainless steel
Maximum discharge-side pressure10 bar
Maximum drive rating90 kW
Type of installationStationary
Maximum flow rate750 m³/h
Minimum flow rate3 m³/h
Maximum speed of rotation3. 500 1/min

 

 

EBARA            GRUNDFOS             KSB            WILO           TSURUMI